<lom:title>
  
<lom:langstring xml:lang="en">Improving the diagnostic quality of fetal MRI: Evaluation of an AI-based post-processing approach for ultrafast image enhancement</lom:langstring>

  
</lom:title>

  
<lom:description>
  
<lom:langstring xml:lang="de">Hintergrund: Die fetale Magnetresonanztomografie (MRT) ist ein entscheidendes
Instrument in der pränatalen Diagnostik, wird jedoch oft durch lange
Aufnahmezeiten und Bewegungsartefakte beeinträchtigt. Künstliche Intelligenz
(KI)-basierte Nachverarbeitungsverfahren, insbesondere Super-Resolution
Algorithmen, bieten eine vielversprechende Möglichkeit, die Bildqualität zu
verbessern, ohne die Scanzeit zu verlängern. Diese Masterarbeit evaluiert die
klinische und technische Wirksamkeit eines solchen KI-basierten Super-resolution
Algorithmus für T2-gewichtete fetale MRT-Sequenzen.
Methodik: in dieser retrospektiven Single-Center Studie wurden 30 fetale MRT-
Datensätze analysiert, welche an einem 3T Philips Scanner akquiriert wurden. Pro
Fall wurden drei T2-gewichtete Turbo-Spin-Echo (TSE) Sequenzen verglichen:
eine konventionell beschleunigte Sequenz (T2 TSE cs), dieselbe Sequenz nach
Anwendung des KI-Algorithmus (T2 AI SR) und eine Standard-hochauflösende
Sequenz (T2 HR cs). Die Bildqualität wurde sowohl anhand quantitativer Metriken
(Signal-Rausch-Verhältnis [SNR], Kontrast-Rausch-Verhältnis [CNR], Edge-Rise
Distance [ERD]) als auch durch eine qualitative Bewertung durch zwei erfahrene
pädiatrische Neuroradiolog*Innen beurteilt. Die qualitative Analyse erfolgte
verblindet, randomisiert und mittels einer 4-Punkte-Likert Skala.
Ergebnisse: Die KI-verbesserte Sequenz (T2 AI SR) wurde qualitativ als
signifikant überlegen gegenüber der konventionellen und der hochauflösenden
Sequenz in den Kategorien Bildschärfe, Gewebekontrast, Gesamtbildqualität und
diagnostische Sicherheit bewertet (alle &lt; 0.001). Diese überlegende diagnostische
Qualität wurde in 38% kürzerer Scanzeit im Vergleich zur hochauflösenden
Referenzsequenz erreicht. Die quantitativen Metriken spiegelten diese subjektive
Präferenz jedoch nicht konsistent wider: Es zeigten sich keine signifikanten
Verbesserungen bei SNR und CNR sowie ein paradoxer Anstieg der ERD-Wertes
für die KI-Sequenz. Dies deutet darauf hin, dass traditionelle Metriken die
perzeptuellen Vorteile der KI-rekonstruktion nur unzureichend erfassen.
Schlussfolgerung: Die KI-basierte Super-Resolution-Nachverarbeitung kann die
wahrgenommene diagnostische Qualität und klinische Nützlichkeit von
ultraschnellen fetalen MRT-Sequenzen erheblich verbessern und gleichzeitig den
Bedarf an hochauflösenden Bildern mit wesentlich längeren Aufnahmezeiten
deutlich reduzieren. Die Ergebnisse unterstützen nachdrücklich die Integration
dieser Technologie zur Steigerung der diagnostischen Sicherheit und der
Workflow-Effizienz in der zeitkritischen und bewegungsanfälligen fetalen
Bildgebung. Die Studie unterstreicht jedoch auch die entscheidende Bedeutung
der perzeptuellen Expertenbewertung, da traditionelle quantitative Metriken den
diagnostischen Nutzen von KI-generierten Bildern möglicherweise nicht
vollständig abbilden.</lom:langstring>

  
</lom:description>

  
<lom:description>
  
<lom:langstring xml:lang="de">Fachhochschule St. Pölten, Masterarbeit 2025, Studiengang Digital Healthcare </lom:langstring>

  
</lom:description>

  
<lom:description>
  
<lom:langstring xml:lang="en">Background: Fetal Magnetic Resonance Imaging (MRI) is crucial tool in prenatal
diagnostics, yet it is often challenged by long acquisition times and motion artifacts,
which can compromise image quality. Artificial intelligence (AI)-based post-
processing techniques, particularly super-resolution, offer a promising solution to
enhance image quality without extending scan duration. This thesis evaluates the
clinical and technical efficacy of an AI-based super-resolution algorithm for T2-
weighted fetal MRI.
Methods: This retrospective, single-center study analyzed 30 fetal MRI datasets
acquired on a 3T Philips scanner. Three T2-weighted turbo spin-echo (TSE)
sequences were compared for each case: a conventional accelerated sequence
(T2 TSE cs), the same sequence enhanced by the AI algorithm (T2 AI SR), and a
standard high-resolution sequence (T2 HR cs). Image quality was assessed using
both quantitative metrics (Signal-to-Noise Ratio [SNR], Contrast-to-Noise ratio
[CNR], Edge-Rise Distance [ERD]) and a qualitative evaluation performed by two
expert pediatric neuroradiologists using a blinded, randomized setup with a 4-point
Likert scale.
Results: The AI-enhanced sequence (T2 AI SR) was qualitatively rated as
significantly superior to both the conventional and high-resolution sequences in
perceived image sharpness, tissue contrast, overall image quality, and diagnostic
confidence (all &lt; 0.001). This superior diagnostic quality was achieved in 38% less
scan time compared to the high-resolution reference. Quantitative metrics,
however, did not consistently align with this subjective preference, revealing no
significant improvements in SNR and CNR and showing a paradoxical increase in
ERD for the AI sequence. This suggests that traditional metrics may not adequately
capture the perceptual benefits of AI-driven reconstruction.
Conclusion: AI-based super-resolution post-processing can substantially improve
the perceived diagnostic quality and clinical usability of ultrafast fetal MRI
sequences while significantly reducing the need for high-resolution images with
substantially longer acquisition times. The findings strongly support the integration
of this technology to enhance diagnostic confidence and workflow efficiency in the
time-sensitive and motion-prone environment of fetal imaging. However, the study
also highlights the critical importance of expert perceptual evaluation, as traditional
quantitative metrics may not fully reflect the diagnostic utility of AI-generated
images.</lom:langstring>

  
</lom:description>

  
<lom:language>eng</lom:language>

  
<lom:keyword>
  
<lom:langstring xml:lang="de">KI-basierte Super-Resolution</lom:langstring>

  
</lom:keyword>

  
<lom:keyword>
  
<lom:langstring xml:lang="de">Fetale Magnetresonanztomografie (MRT)</lom:langstring>

  
</lom:keyword>

  
<lom:keyword>
  
<lom:langstring xml:lang="de">Bildqualität &amp; diagnostische Sicherheit</lom:langstring>

  
</lom:keyword>

  
<lom:keyword>
  
<lom:langstring xml:lang="de">Quantitative vs. perzeptuelle Bewertung</lom:langstring>

  
</lom:keyword>

  
<lom:keyword>
  
<lom:langstring xml:lang="en">AI-based super-resolution</lom:langstring>

  
</lom:keyword>

  
<lom:keyword>
  
<lom:langstring xml:lang="en">Fetal magnetic resonance imaging (MRI)</lom:langstring>

  
</lom:keyword>

  
<lom:keyword>
  
<lom:langstring xml:lang="en">Image quality &amp; diagnostic confidence</lom:langstring>

  
</lom:keyword>

  
<lom:keyword>
  
<lom:langstring xml:lang="en">Quantitative vs. perceptual evaluation</lom:langstring>

  
</lom:keyword>

  
</lom:general>

  
<lom:lifecycle>
  
<lom:datetime>2025-12-15T11:50:04.791Z</lom:datetime>

  
<lom:contribute>
  
<lom:role>
  
<lom:source>
  
<lom:langstring xml:lang="x-none">LOMv1.0</lom:langstring>

  
</lom:source>

  
<lom:value>
  
<lom:langstring xml:lang="x-none">Author</lom:langstring>

  
</lom:value>

  
</lom:role>

  
<lom:centity>
  
<lom:vcard>BEGIN:VCARD
VERSION:3.0
N:Mittermaier;Rebecca;
FN:Rebecca Mittermaier
END:VCARD</lom:vcard>

  
</lom:centity>

  
</lom:contribute>

  
</lom:lifecycle>

  
<lom:educational>
  
<lom:learningresourcetype>
  
<lom:source>
  
<lom:langstring xml:lang="x-none">https://w3id.org/kim/hcrt/scheme</lom:langstring>

  
</lom:source>

  
<lom:id>https://w3id.org/kim/hcrt/text</lom:id>

  
<lom:entry>
  
<lom:langstring xml:lang="de">Textdokument</lom:langstring>

  
<lom:langstring xml:lang="en">Text</lom:langstring>

  
</lom:entry>

  
</lom:learningresourcetype>

  
</lom:educational>

  
<lom:rights>
  
<lom:copyrightandotherrestrictions>
  
<lom:source>
  
<lom:langstring xml:lang="x-none">LOMv1.0</lom:langstring>

  
</lom:source>

  
<lom:value>
  
<lom:langstring xml:lang="x-none">yes</lom:langstring>

  
</lom:value>

  
</lom:copyrightandotherrestrictions>

  
<lom:description>
  
<lom:langstring>https://rightsstatements.org/vocab/InC/1.0</lom:langstring>

  
</lom:description>

  
</lom:rights>

  
<lom:technical>
  
<lom:format>application/pdf</lom:format>

  
<lom:size>9407194</lom:size>

  
<lom:location>https://phaidra.ustp.at/o:7649</lom:location>

  
<lom:thumbnail>
  
<lom:url>https://phaidra.ustp.at/api/object/o:7649/thumbnail</lom:url>

  
</lom:thumbnail>

  
</lom:technical>

  
<lom:classification>
  
<lom:purpose>
  
<lom:source>
  
<lom:langstring xml:lang="x-none">LOMv1.0</lom:langstring>

  
</lom:source>

  
<lom:value>
  
<lom:langstring xml:lang="x-none">discipline</lom:langstring>

  
</lom:value>

  
</lom:purpose>

  
</lom:classification>

  
</lom:lom>